9 • troubleshooting – Hunter 28704 52 Skyline User Manual
Page 17
17
42449-01 • 11/09/10 • Hunter Fan Company
Problem: Nothing happens; fan does not move.
1 . Turn power on, replace fuse, or reset breaker .
2 . Loosen canopy, check all connections according to the wiring the fan section .
3 . Check the plug connection in the switch housing .
4 . Push motor reversing switch firmly left or right to ensure that the switch is engaged .
5 . Pull the pull chain to ensure it is on .
6 . Remove the shipping bumpers .
Problem: Noisy operation.
1 . Tighten the blade assembly screws and blade iron armature screws until snug .
2 . Check to see if the blade is cracked . If so, replace all the blades .
Problem: Excessive wobbling.
1 . If your fan wobbles when operating, use the enclosed balancing kit and instructions to balance the fan .
2 . Tighten all blade iron screws .
3 . Turn power off, support fan very carefully, and check that the hanger ball is properly seated .
Problem: Lights shut off suddenly, but fan is still operating
1 . Check to make sure the wattage and type of the light bulbs that are installed meet the specifications on
the MAX wattage sticker affixed to the light socket .
2 . Turn the power to the fan off at the wall switch . Wait 5 minutes, then resume power to the fan .
Problem: CFL bulbs flicker when controlled by a dimming remote or wall control
1 . CFL light bulbs are not usually made for dimming . Replace the CFL bulbs with dimmable light bulbs, or
install the fan in a location without a dimming control .