Step 3.
On the Hydraulic Spool Valve remove the “Return” hose on the valve body for the conveyor. Install the 1/2” by
17” hydraulic hose from the valve body to the Talc Applicator Control Valve. Connect hose to #3 on the talc
applicator valve body. Tighten all fittings once installed.
Step 4.
Install the last 1/2” x 17” hose. This hose connects to # 4 on the Talc Applicator Valve Body and to the Conveyor
Return Hose, which was removed from the Hydraulic Valve Body in step 3. Tighten all fittings once installed.
Remove Conveyor Return
Hose and 90 Deg. Fitting.
17” Hydraulic
Hose
17” Hydraulic
Hose
Conveyor
Return Hose
#3
#4
Note: 1/4” Hoses will be installed in step 8.