beautypg.com

J&M Talc Applicator Set Up For Seed Tender 275 & 375 User Manual

Page 3

background image

Step 3.

On the Hydraulic Spool Valve remove the “Return” hose on the valve body for the conveyor. Install the 1/2” by

17” hydraulic hose from the valve body to the Talc Applicator Control Valve. Connect hose to #3 on the talc

applicator valve body. Tighten all fittings once installed.

Step 4.

Install the last 1/2” x 17” hose. This hose connects to # 4 on the Talc Applicator Valve Body and to the Conveyor

Return Hose, which was removed from the Hydraulic Valve Body in step 3. Tighten all fittings once installed.

Remove Conveyor Return

Hose and 90 Deg. Fitting.

17” Hydraulic

Hose

17” Hydraulic

Hose

Conveyor

Return Hose

#3

#4

Note: 1/4” Hoses will be installed in step 8.