0 wiring – J&M 375ST User Manual
Page 37
34
Scroll
4.0 Wiring
4.0 Wiring
Wireless Remote 2 (optional)
Starts/Stops Motor
Raises/Lowers Conveyer
Opens/Closes Tank Doors
Hydraulic Conveyer/Auger Swing
Electronic Auto Scale Shutoff
To Toggle Switch
Ground
Same as Figure 4.1
To Scale Display/Interface
Section 4.3
1. Turn Scale Head, Wireless Remote and Wireless Toggle Switch on.
-The main screen showing gross and tared weight will display
2. Press and release Scroll on the Wireless Remote
-The setting for door weight and door selection (front or rear) will display
3. Press and hold scroll until the weight value starts to flash
4. Using the up and down arrows just below the display in the center of the remote, adjust the desired dispense weight
5. Press and release Scroll
-The door setting will flash
6. Using the up and down arrows just below the display in the center of the remote, select which door you wish to dispense from
7. When settings are acceptable, press and hold scroll for 3 seconds
-The main screen will display again
8. Press conveyor start to dispense the set amount of seed from the desired door
-The door will automatically shut when the set amount of seed is dispensed and the conveyor will turn off shortly after
9. To dispense the same amount of seed from the same door repeatedly, repeat steps 2, 3, 7, and 8
Use these buttons to adjust “Dispense
Amount” and “ Door To Dispense From”
Settings
Main Screen
Auto Scale Shutoff Screen
Auto Scale Shutoff Directions for Wireless Remote 2
Wireless Reciever 2
4
JM0015005
JM0014999