beautypg.com

Repair and assembly, Pilot valve removal, Required tools – All-Flo A050 Series 1/2 Aluminum User Manual

Page 18: Warning

background image

all-flo.com

18

PILOT VALVE REMOVAL

STEP 1

Using the screwdriver, remove

three “Phillips Flat-Head Mach

Screws (#6-32 x 7/16)” in order to

remove the “Retaining Plate”.

Repeat for both sides of the pump.

STEP 2

Remove the diaphragm rod and

the pilot sleeve assembly from the

“Intermediate”.

STEP 3

Remove both “Lip Seals

(Diaphragm Rod)” and both “End

Spacers (Pilot Sleeve)” from the

pilot sleeve assembly. Remove

both “O-Rings (End Spacer)” from

both “End Spacers (Pilot Sleeve)”.

REQUIRED TOOLS

1) One Screwdriver, Phillips
2) Two Wrenches,

7

/

16

Inch

WARNING

Prior to servicing the pump, ensure that the air

and fluid lines are closed and disconnected. While wearing personal

protective equipment, flush, drain and process liquid from the

pump in a safe manner.

STEP 4

Remove three “Inner Spacers

(Pilot Sleeve)” and four “O-Rings

(Pilot Sleeve)” from the pilot

sleeve assembly.

STEP 6

Remove the “Pilot Sleeve” from

the disassembled “Diaphragm

Rod Assembly”.

REPAIR AND ASSEMBLY

STEP 5

Using two 7/16 inch wrenches,

dissemble the “Diaphragm Rod

Assembly” into its two parts.