Motec appendices 75 – MoTeC ACL VIM User Manual
Page 79

MoTeC
Appendices
75
ACL Errors
These errors are generated by the ACL communications system.
2
FRAMING
Incorrect number of samples received.
256
BAD CONFIG
Configuration mismatch between ACL
and device. Resend the configuration.
512
NO DATA
VIMCOM packets have not been found.
Either there is a wiring fault or ACL
Connections is setup incorrectly.
2048
WRONG DATA
VIMCOM packet has bad length.
4096
BUS WARNING
More than 96 errors have occurred on
the CAN bus. Check wiring and
termination resistors. The CAN bus may
still be operational.
8192
BUS OFF
More than 255 errors have occurred on
the CAN bus. CAN communications is
suspended when this error occurs.
Check wiring, termination resistors and
the CAN baud rate. Also check that CAN
HI and CAN LO are correct (not
swapped).
VIMCOM Device Errors.
These error codes are sent once by the VIMCOM device on resuming
data transmission and therefore indicate why data was previously not
being transmitted.
4097
STARTUP
Device has restarted (normally due to
power up) Data is not sent until sync is
achieved.
4098
HALT
Data not sent due to deliberate halt. For
example configuration or firmware being
sent.
4099 OVERRUN
Data
not
sent due to transmit buffer
overrun (possibly due to CAN bus too
busy)
4100
SYNC TIMEOUT
Data not sent due to ACL sync message
timeout (sync not received from ACL)
4101
CAN ERROR
Data not sent due to error on CAN bus