DETAILED SPECIFICATIONS - VDC Model No. 24041-AA (con’t.)
Absorption mode transitions to Float mode conditions in AGM setting:
Mode: 1) Charging current
2) 5 Hours Time-out: after 5 Hours unit switches to Float Charge Mode
Absorption mode Thermal Runaway Protection: Stops Charging when the second current sample is
larger the first current sample (Positive dI/dt)
Switch to Float mode in Bulk charge or Absorption mode when Battery type Button is Pressed For
Seconds or longer.
GREEN
Charge - Float LED will blink
Float Charge output Voltage control
26.1 ±0.25 Vdc
Float Charge current control
(1A Rate) .5 Adc ±0.25
(2A Rate) 1 Adc ±0.25
(4A Rate) 2 Adc±0.25
Float charge transitions to PWM Float Charge Mode after 1 Hour
Float Pulse Charge voltage control 26.1@24°V ±0.25 Vdc
Float Pulse Charge current control:
(1A Rate) .5 Adc ±0.25
(2A Rate) 1 Adc ±0.25
(4A Rate) 2 Adc ±0.25