DETAILED SPECIFICATIONS - VDC Model No. 24041-AA (con’t.)
•
Charging Output Control Characteristics
•
Charging Flow : Battery condition detect>Soft Start Charge>Bulk Charge>Absorption
Charge>Sulphate Check>Float Charge
•
Soft Start Charging Activity conditions: Battery Voltage is over 6 Vdc and less than 21Vdc
(the charger will start at 1A mode & Gel mode automatically)
•
Soft Start Charging output current control: (1A / 2A / 4A mode) 1 / 2 / 4 ±0.25 Adc
•
Soft Start Charging Time Limited: (Stop charge If battery cannot be charged over 10.5V after
6 hrs, Error LED flash indicated) 6 ±0.25 Hours
•
Bulk Charging Activity conditions: Battery Voltage is over 21Vdc
(the charger will start at
1A mode & Gel mode automatically)
•
Bulk Charging Current control at 1A mode: (Selected by pressing Charge Rate Button)
1 +0.17 / -0 Adc
•
Bulk Charging Current control at 2A mode: (Selected by pressing Charge Rate Button)
2 +0.20 / -0 Adc
•
Bulk Charging Current control at 4A mode: (Selected by pressing Charge Rate Button)
4 +0.22 / -0 Adc
•
Max. rated output voltage and current: 26.0V at 4Adc 27.2V at .25Adc
•
Bulk Charging Time Limited: (Stops charge If battery cannot be charged reach 28.2/28.8/28.2V
after 20 hrs, error LED flash indicated) 20 ±1 Hours