BatteryMINDer
®
Aviation-Adjusted Models
E
12248-AA-S2, S3 & S5
Rev. C-071213-1
Page 9
P/N VDC
E
12248-AA-Sx-MNL
SIMPLIFIED OPERATING INSTRUCTIONS
Read and thoroughly understand ALL SAFETY Instructions, pages
3 - 7 including Preparing to Charge, DC Connection Precautions,
Unit Location and Qualifying Your Battery BEFORE proceeding
further.
1.
Attach Battery Clips (
7
) (supplied), to output cordset of charger (
4
).
2.
Attach output to battery terminals:
RED band = Positive
+
BLACK band = Negative -.
3.
Ambient Temperature Sensor,
ATS-1 (
8
), comes already installed on
the Temperature Sensor input connector (
3
). Do not detach.
The
Ambient Temperature Sensor (ATS-1) is mandatory when used
with all Aviation batteries.
4.
Plug AC power cord (
5
) into a 220 - 240 Vac electrical outlet.
5.
Observe Reversed Polarity
GREEN/RED LED indicator (
1a
):
If lit RED, reverse battery connector attachments on battery.
6.
Observe
Charging - Maintenance/Desulfating GREEN
LED
indicator (
1c
)
:
Solid = charging
Blinking = maintaining battery(s).
Charger will automatically start within 30 seconds or less.
7.
Observe
Battery Connected - Error LED Indicator (
1a
):
Must be lit
GREEN
1
.
Be sure Maintaining - Desulfating LED (
1c
)
is BLINKING before leaving
unit for an extended period of time. Otherwise, press & hold the
Maintenance button (
2
) for 3 seconds.
IF IN DOUBT REGARDING ANY OF THE ABOVE, REFER TO
Detailed
Operating Instructions, page 12.
1
See full instructions if not lit
GREEN.