beautypg.com

Batteryminder – BatteryMINDer E12248-AA-Series User Manual

Page 17

background image

BatteryMINDer

®

Aviation-Adjusted Models

E

12248-AA-S2, S3 & S5

Rev. C-071213-1

Page 17

P/N VDC

E

12248-AA-Sx-MNL

The chart below shows the need to regulate the output voltage of the

charger to ensure against over or under charging your battery over a

wide range of temperatures. Using your Ambient Temperature Sensor

(

ATS-1) will accomplish this better than any other known method.

*Values shown are based on information supplied by Concorde Battery Co., effective

May 15, 2012. Values for batteries manufactured by other aviation battery companies

are believed to comparable. We strongly recommend checking with the appropriate

dealer or battery manufacturer to be certain.

CHARGE AND FLOAT VOLTAGES AT

VARIOUS TEMPERATURE RANGES

Temp

°F

Optimum Charge

Optimum Float

Temp

°C

-S2

-S3

-S5*

-S2

-S3

-S5*

≥120

13.35

14.00

13.35

12.95

13.00

13.20

≥49

110 – 120

13.50

14.20

13.50

12.95

13.10

13.20

43 – 49

100 -110

13.65

14.30

13.65

12.95

13.20

13.20

38 – 43

90 – 100

13.80

14.40

13.80

12.95

13.30

13.20

32 – 38

80 – 90

13.95

14.50

13.95

12.95

13.40

13.20

27 – 32

70 – 80

14.10

14.70

14.10

13.05

13.60

13.30

21 – 27

60 – 70

14.25

14.85

14.25

13.20

13.85

13.45

16 - 21

50 – 60

14.40

15.00

14.40

13.35

14.10

13.60

10 - 16

40 – 50

14.55

15.20

14.55

13.50

14.25

13.75

4 - 10

≤40

14.70

15.50

14.70

13.65

14.45

13.90

≤4