beautypg.com

Table 2 – BatteryMINDer 1510 User Manual

Page 8

background image

Rev. B-012314

Page 8

P/N VDC1500-10MNL

BatteryMINDer

®

&

Plus with SmarTECHnology

®

Model 1500 Series

12V Charger - Maintainer

Automatic Full-Time Desulfator

LED INDICATIONS

POWER

DESULFATION

CHARGING

FAULT

LOW BATTERY

MAINTAINING

LED Color

GREEN

/

RED

BLUE

/

YELLOW

GREEN

1

AC Power connected, Battery

disconnected

ON

OFF

OFF

2

AC Power connected, battery

disconnected >10 sec., charger in

sleep mode

FLASH

OFF

OFF

3

AC Power connected, battery initial

condition detected for 3 sec., initial

battery < 10.5V

ON

ON

OFF

4

AC Power connected, battery initial

condition detected for 3 sec., initial

battery > 10.5V

ON

OFF

OFF

5

AC Power connected, soft start

charging, bulk charging and

absorption charging

ON

FLASH

FLASH

6

Sulfation check mode

ON

OFF

FLASH

7

Maintenance charging if battery

voltage < 12.5V at sulfation check

mode

ON

ON

ON

8

Maintenance charging if battery

voltage > 12.5V at sulfation check

mode

ON

FLASH

ON

9

Charger output clips shorted,

battery polarity reversed, battery

voltage < 3V

ON

OFF

OFF

10

Battery timed-out during soft start

charging, bulk charging

FLASH

OFF

OFF

Remarks: Blue LED flash rate: ON 100 msec., OFF 2 sec.; Green LED Flash rate: ON 0.5 sec., OFF 0.5 sec.