TROUBLESHOOTING

VDC Electronics Technical Support: (800) 379-5579 x6

• Unit does not have an output unless connected to a battery. In order to

test the output using a meter, connect the meter to your battery. When you

connect the unit, you will see the voltage rise.

• If the unit is not in maintenance after 72 hours (solid GREEN), check

to make sure your battery meets the minimum voltage of 3.0 volts.

Unit will not operate if battery is below the minimum voltage of 3.0 volts.

If there is a load on your battery, disconnect it and charge again.

If the problem persists, your battery may be shorted or too badly sulfated.

Visit our learning center at BatteryMINDers.com for additional battery

information.

MAINTAINING MULTIPLE BATTERIES

Batteries should be charged individually. To properly maintain multiple

batteries they should all be the same type (gel, flooded or AGM) and condition.

It is OK to mix deep cycle and starter.

Charge each battery individually before

connecting together. Never connect batteries at different states of charge. The

charged battery will rapidly transfer energy to the discharged battery possibly

causing catastrophic failure. Once the batteries are charged, use 18 gauge

or greater wire to connect the batteries or

for greatest safety protection and

ease of use, consider investing in the BatteryMINDer Y-Connector Model

210AY with SmarTECHnology*.

See diagram on the Page 13 for the most common multiple battery

configuration.

You must connect multiple batteries of the same voltage, wire them in parallel

(BatteryMINDer positive to positive A to positive B, BatteryMINDer negative to

negative A to negative B). .

If connecting 2 batteries of half your unit’s voltage (example: 6V batteries on a

12V unit), wire them in series (BatteryMINDer positive to positive A, negative

A to positive B, negative B to BatteryMINDer negative). When wired in series

they act as one large system at the combined voltage (example: 6V+ 6V =

12V). You can connect these systems in a series parallel configuration in

order to charge or maintain 4 or batteries in groups of 2.

*BatteryMINDer

®

has developed a simple, safe and inexpensive method of connecting multiple

batteries they call SmarTECHnology

®

-Y. Using their single SmarTECHnology-Y connector,

two batteries can be maintained simultaneously using just a single output charger designed to

maintain batteries. Adding additional Y-connectors allows from four (4) to eight (8) batteries to be

connected depending on the maintenance charger capability.