Common multiple battery configurations – BatteryMINDer 1510 User Manual
Page 14
Rev. B-012314
Page 14
P/N VDC1500-10MNL
BatteryMINDer
®
&
Plus with SmarTECHnology
®
Model 1500 Series
COMMON MULTIPLE BATTERY CONFIGURATIONS
Safety & Protection
Safety standards:
Complies with the requirements of the
Standard(s) for Battery Chargers (UL-1236) and
is identified with the ETL Listed Mark
EMC standard:
FCC part15
Input-Output
insulation test:
1240Vac 60Hz
5mAac, no breakdown
Cooling:
By natural cooling
Electrical Cable & Physical Parameters
Input socket
UL 2 PIN wall mount
Output 1
10 feet 18AWG X2 105°C with quick connector +
2 feet 18AWG X2 with battery clamp;
2 feet 18AWG X2 with ring terminal (for 1510)
Plastic enclosure
dimension
100 (L) x 65 (W) x 30 (H) mm
3.34 (L) x 2.56 (W) x 1.18 (H) in.
Operating temperature
-10 to 40°C
14 to 104°F
Storage temperature
-25 to 85°C
-13 to 185°F
Operating humidity range 0 to 90% RH
Weight
<1 lb.