beautypg.com

Operation, Fresh operation, Emergency operation and test operation – haier HSU-09RS03_R2(SDB) User Manual

Page 10: For smart use of the air conditioner, Emergency operation, Test operation, Air filter cleaning, About change-for-fresh-air function

background image

FRESH Operation

Exhaust the vitiated air from the room, and inhale fresh air.

(This function is unavailable on some models.)

Emergency operation and test operation

Pi

Pi Pi

displayed on the remote controller and

and the change-for-fresh-air

function

For twice press , the display " "

disappears and the change-for-fresh-

air function operation is canceled.

Note

If the unit didn’t install change-for-fresh-air electrical

engine, change-for-fresh-air function is not available.

After the change-for-fresh-air function is initiated,
the outside air can enter the indoors through the
change-fresh-air tube thereby keeping the indoor

About change-for-fresh-air function

Setting the change-for-fresh-air function under
the shutdown status, press the fresh air key and
the remote controller displays the on status of air
flow, low wind,and change-for-fresh-air functions,
and now can set the timing open, timing close

The dual fresh air has a memory function, which

can be cancelled by pressing the key one time.

Under the smart mode, after the machine has

Operation

“ ” is displayed on the display board,

been running for a while,the dual fresh air
function will be started automatically,it will be
automatically stopped after continuously running

Emergency Operation:

the room

temperature is below 16 C, do

o

Test operation:

Use this switch in the test operation when

It is not possible to operate in dry mode.

Room

temperature

Operation

mode

Designated

temperature

Timer

mode

Air flow

ABOVE 23

O

C

BELOW 23 C

COOLING

HEAT

23

O

C

26

O

C

NO

NO

AUTOMATIC

AUTOMATIC

(cooling only uint)

Room

Operation

mode

Designated

temperature

Timer

mode

Air flow

BELOW 23

O

C

FAN

26

O

C

NO

AUTOMATIC

Test operation switch is the same as

Use this operation only when the remote

controller is defective or lost.

When the emergency operation switch
is pressed,the"Pi" sound is heard once,

In this operation,the system automatically selects the
operation modes,cooling tor fan or heat, according to

Continue to press the test operation switch for more than
5 seconds. After you hear the

"Pi" sound twice,release

your finger from the switch:the cooling

operation starts

O

Air Filter cleaning

Clean the filter

Attach the filter

Close the inlet grille

Once every
two weeks

Open the inlet grille by pulling

Remove the filter

Push up the filter’s center tab slightly until it is
released from the stopper, and remove the filter

Use a vacuum cleaner to remove dust, or wash

the filter with water. After washing, dry the filter

For smart Use of The Air Conditioner

AM

SMART

Press FRESH button “ ” is

operation begins.

and time control switch.

air fresh.

for a while.

temperature

which means the start of this operation.

the room temperature.

emergency switch.

not use it in the normal operation.

with the air flow speed

"Hi".

downward.

completely in the shade.

it upward

Attach the filter correctly so that the
“FRONT” indication is facing to the

completely fixed behind the stopper.
If the right and left filters are not

front. Make sure that the filter is

attached correctly, that may cause defects.

10