Command line format: COMMAND
Current value will have one decimal place for models 1687B and 1688B, and two
decimal places for Model 1685B.
Command code &
Return value
Function
Example
Input command:
VOLT{
Return value:
OK[CR]
Set voltage level
Input command:
VOLT010[CR]
Return value:
OK[CR]
Sets voltage level to 1.0 V
Input command:
CURR{
Return value:
OK[CR]
Set current level
Input command:
CURR025[CR]
Return value:
OK[CR]
Sets current level to 2.5 A
Input command:
PROM{ voltage>}{ current>}{ voltage>}{ current>}{ voltage>}{ current>}[CR] Return value: OK[CR] Set power supply preset memory values 000-XXX 000-XXX Input command: PROM011022033044055066 Return value: OK[CR] Sets preset 1 voltage and current to 1.1 V and 2.2 A, preset 2 voltage and current to 3.3 V and 4.4 A, and preset 3 voltage and current to 5.5 V and 6.6 A Input command: GETS[CR] Return value: [voltage][current][CR] OK[CR] Get voltage and current setting values from power supply [voltage] = 000-XXX [current] = 000-XXX Input command: GETS[CR] Return value: 025051 OK Indicates voltage setting is 2.5 V and current setting is 5.1 A