Ctivating, Omponents in, 4 activating components in your hand – Autel PowerScan PS100 User Manual
Page 13

12
Figure 10
If the LCD readings are abnormal, there is a problem with this 
sensor. 
3.4 Activating Components in Your Hand
While the tool is in DC Voltage mode, by using the probe tip in 
connection with the auxiliary ground lead, components can be 
activated right in your hand, thereby testing their functions. 
Connect the auxiliary ground lead to the negative terminal or ground 
side of the component being tested. Then contact the probe tip to the 
positive terminal of the component, the green LED should light, 
indicating continuity through the component. 
While keeping an eye on the green LED, quickly press and release 
the power switch forward. If the green LED went out and the red 
LED came on, you may proceed with further activation. Rock the 
power switch forward and hold it down to provide power to your 
component. With the power switch rocked forward, power will flow 
from the positive lead on the battery into the probe tip, through the 
tip into the component‟s positive terminal, into the component and 
out of the component, through the auxiliary ground lead and back 
into the tool, and back to the vehicle‟s battery‟s ground. (Figure 11) 