Material safety data sheet – Alpha Technologies Spill Control Barrier System User Manual
Page 24

Alpha Industrial Power
Spill Control Barrier System
Revision Date: March 18, 2008
MSDS No. ANFC (B)
Installation Manual
Page 22 of 25
MATERIAL SAFETY DATA SHEET
1. MATERIAL IDENTIFICATION
ProductName:
NOVOLAC FLOOR COATING (HARDENER), PART-B
ChemicalFamily:
AMINE MIXTURE
Company Name:
Eastern Resins Corp.
1174RiverStreet
BUSINESS PHONE:
(401) 769-6700
Woonsocket, RI 02895, USA
EMERGENCY PHONE: (800) 255-3924
2. COMPOSITION
Exposure Limits
ACGIH
OSHA
ChemicalName
Wt%
TLV-TWA
PE L
Cycloaliphatic amine
50-70
N/E
N/E
Aliphaticamine
30-50
N/E
N/E
Specific ingredients are considered a Trade Secret
Abbreviations: N/E - NOT ESTABLISHED
* - Materials are in Non-Airborne form
3. HEALTH HAZARDS
PrimaryRoutesofExposure:
Eyes: Yes
Skin: Yes
Inhalation:
Yes
Eye Contact: Cause severe irritation and may cause burn.
Skin Contact: Cause irritation and sensitization. Symptomscan be immediate or delayed several hours.
Inhalation: Can cause respiratory tract irritation.
Ingestion: Can cause nausea, headache, and gastrointestinal irritation.
Other: Preexisting skin sensitization may be aggravated by exposure to this product.
4. FIRST AID MEASURES
Eyes: Flush eyes thoroughly with water for at least 15 minutes while holding eyelids open. Seek medical attention.
Skin: Remove contaminated clothing. Wipe excess from skin and wash the affected area thoroughly with soap and water. Wash
contaminated clothing thoroughly before reuse.
Inhalation: Remove to fresh air, and provide oxygen or artificial respiration if needed. Obtain medical attention; symptoms can be
delayed up to several hours.
Ingestion: DO NOT induce vomiting. Give 1-2 cups of water or milk unless the person is drowsy, convulsing, or unconscious. Get
medical attention.
5. FIRE FIGHTING MEASURES
Flammable Properties: Flash Point:
>200
o
F (PMCC)
ExplosiveLimits:
Notapplicable
Auto-IgnitionTemperature:
Not applicable
Hazardous Decomposition Products:
oxides of nitrogen, Carbon monoxide, carbon dioxide and other organic materials.
EXTINGUISHING MEDIA AND FIRE FIGHTING INSTRUCTIONS: When sufficiently large quantities are present,
firefighters should be equipped with full bunker gear, including a positive pressure, NIOSH approved, self-contained breathing
apparatus. Extreme heat or water contamination may cause closed containers to explode.
Extinguishing Media: Use carbon dioxide, dry chemical or appropriate foam.
6. ACCIDENTAL RELEASE MEASURES
Ventilate the spill area and evacuate if necessary. Remove all ignition sources. Dike and contain large spills. Flush area with water
spray. Clean-up personnel should use adequate protective equipment.