Elmo Rietschle L-BV5 Supplementary instructions User Manual
Page 7

Concerning 5 Installation
© Gardner Denver Deutschland GmbH
7 / 12
610.44440.40.200
NOTE
The liquid level monitoring device (Fig. 1,
page 6) is equipped with a shut-off valve which
opens after the unit is switched off and closes
again before starting up after the filling level has
been regulated.
If a connection between the device and the
ambient atmosphere is not possible, or
undesirable, due to the type of media used, the
line should be routed back into the equipment
behind the shut-off valve on the suction side in a
suitable way (Fig. 1. page 6).
2BV2 0..
2BV5 1..
Type
Minimum h
f min
[mm]
Maximum h
f max
[mm]
Minimum h
f min
[inches]
Maximum h
f max
[inches]
2BV2 060
2BV2 061
75 95 2.95
3.74
2BV2 070
2BV2 071
95 120 3.74
4.72
2BV5 110
2BV5 111
116 156 4.57 6.14
2BV5 121
130
170
5.12
6.69
2BV5 131
140
185
5.51
7.28
2BV5 161
175
235
6.89
9.25
Fig. 2 Operating liquid level
0
h
f min
h
f max
0
h
f min
h
f max