Concerning 5 Installation

© Gardner Denver Deutschland GmbH

7 / 12

610.44440.40.200

NOTE

The liquid level monitoring device (Fig. 1,
page 6) is equipped with a shut-off valve which
opens after the unit is switched off and closes
again before starting up after the filling level has
been regulated.
If a connection between the device and the
ambient atmosphere is not possible, or
undesirable, due to the type of media used, the
line should be routed back into the equipment
behind the shut-off valve on the suction side in a
suitable way (Fig. 1. page 6).


2BV2 0..

2BV5 1..

Type

Minimum h

f min

[mm]

Maximum h

f max

[mm]

Minimum h

f min

[inches]

Maximum h

f max

[inches]

2BV2 060

2BV2 061

75 95 2.95

3.74

2BV2 070

2BV2 071

95 120 3.74

4.72

2BV5 110

2BV5 111

116 156 4.57 6.14

2BV5 121

130

170

5.12

6.69

2BV5 131

140

185

5.51

7.28

2BV5 161

175

235

6.89

9.25

Fig. 2 Operating liquid level