Malfunctions: Causes and elimination
Fault
Cause
Troubleshooting
Important
Final pressure (max.
vacuum) is not
reached
Pump or system vacuum
leaks
Check the pipe work and
screw connections for leaks
and to ensure that they are
firmly seated
Section 7.2
Insufficient cooling water
Note cooling water
consumption from data sheet
Section 9
The mesh filter is dirty
Clean or replace the mesh
filter
Section 7.2.2
Section 7.4
Pump gets too hot
Ambient or intake temperature
is too high
Recheck operating
parameters
Section 2.3
Cooling air supply is
obstructed
Check environmental
conditions
Section 5.1
Clean the cooling fins
Section 7.2
The cooling water system is
obstructed
Check the cooling water
system and the pipes
Section 7.2
Insufficient cooling water
Note cooling water
consumption
Section 9
Cooling water inflow is too hot Note the max. intake
temperature
Section 9
The pump makes a
abnormal noise
Deposits on the rotors
Clean the compression
chamber and the rotors
Elmo Rietschle
Service
Please contact Elmo Rietschle Service for other malfunctions or those that cannot be eliminated.