beautypg.com

Elmo Rietschle S-VSI 300(44) User Manual

Page 32

background image

32

|

www.elmorietschle.com © Gardner Denver Schopfheim GmbH, Gardner Denver Deutschland GmbH

Malfunctions: Causes and elimination

Fault

Cause

Troubleshooting

Important

Pump is switched
off by the motor
protection switch

Power Supply/ Frequency
does not correspond with the
motor data

Check by qualified electrician

Section 5.5

Connection to motor leads is
not correct

Motor protection switch is not
set correctly

Motor protection switch is
triggered too quickly

Use a motor protection switch
with an overload-dependent
delayed switch off that takes
into consideration the short
term excess current at start
up

Pumping capacity is
insufficient

The mesh filter is dirty

Clean or replace the mesh
filter

Section 7.2.2
Section 7.4

The suction pipe is too long or
too narrow

Check the hose or the pipe

Section 5.3

Pump or system vacuum
leaks

Check the pipe work and
screw connections for leaks
and to ensure that they are
firmly seated

Section 7.2

8