©Copyright 2013 Liberty Pumps Inc. All rights reserved

- 2 -

1.

X

General Information

X

Before installation, read the following instructions carefully. Each Liberty pump is individually factory tested to insure proper

performance. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free

service.

Risk of electric shock. Always disconnect the pump from the power source before handling or making

adjustments.

The electrical connections and wiring for a pump installation should only be made by qualified personnel.

This pump is supplied with a grounding conductor and grounding-type attachment plug. To reduce the risk of

electric shock, be certain that it is connected only to a properly grounded, grounding-type receptacle.

DO NOT bypass grounding wires or remove ground prong from attachment plugs.

DO NOT use an extension cord.

This pump requires a separate, properly fused and grounded branch circuit. Make sure the power source is

properly sized for the voltage and amperage requirements of the pump, as noted on the nameplate.

The electrical outlet shall be within the length limitations of the pump power cord, and at least 4 feet above floor

level to minimize possible hazards from flood conditions.

The installation must be in accordance with the National Electric Code, Uniform Plumbing Code, International

Plumbing Code, as well as all applicable local codes and ordinances.

Sump and sewage pumps often handle materials which could cause illness or disease. Wear adequate protective

clothing when working on a used pump or piping.

Never enter a pump basin after it has been used. Sewage and effluent can emit several gases which are

poisonous.

Keep clear of suction and discharge openings. To prevent injury, never insert fingers into pump while it is

plugged in.

DO NOT use this product for flammable or corrosive liquid.

DO NOT use this product in applications where human contact with the pumped fluid is common (such as

swimming pools, fountains, etc.)

NEVER dispose of materials such as paint thinner or other chemicals down drains, as they can chemically attack

and damage pump components, potentially causing product malfunction or failure.

DO NOT run pump dry, this product is intended to be partway submerged when operating.

Do not use these pumps in water over 140

F.

The Uniform Plumbing Code (UPC) states that sewage systems shall have an audio and visual alarm that signals

a malfunction of the system, to reduce the potential for property damage.

A 20 amp breaker is recommended for 115V pumps.

Note: Manual models (“M”

suffix), require a separate

approved pump control device or

panel for automatic operation.

Operation of these models will be

according to the control selected.

Make

sure

the

electrical

specifications of the control

selected properly match the

electrical specifications of the

pump. Always refer to control

panel instructions for proper

installation.

Model

HP

Volts

Phase

Full

Load

Amps

FNPT

Discharge

Automatic or

Manual*

PRG101A

1

115

1

12

2”

Automatic

PRG101A-2

1

115

1

12

2”

Automatic

PRG101M

1

115

1

12

2”

Manual

PRG101M-2

1

115

1

12

2”

Manual

PRG102A

1

230

1

6

2”

Automatic

PRG102A-2

1

230

1

6

2”

Automatic

PRG102M

1

230

1

6

2”

Manual

PRG102M-2

1

230

1

6

2”

Manual