Gorman-Rupp Pumps SM4G1-X30 460/3 1002211 thru 1241783 User Manual
Page 14
OM−04417
SM SERIES
PAGE B − 9
INSTALLATION
Table B-3. MSHA Specifications And Approval Data (continued)
MSHA Approval Number (All Models)
2G−3971A−0
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commonwealth of Pennsylvania Approval Number (Only Models With *)
BFE−637−77
. . . . . . . . .
Model
Motor Cable
Trailing Cable
Motor
G-R P/N
MSHA No.
*SM4K1-X15 460/3
*SM4K1-X15 575/3
XP−3932−0
XP−3932−0
16521
16521
No. 8, 3 Conductor,
Type G-GC, .97"
$
.03" O.D., Protected By
An Instantaneous Trip
Circuit Breaker, Set At
200 Amps Max., MSHA
Flame Resistance,
600/2000 Volt, 90
_C.
Max. Length: 500 Ft. -
Customer Furnished
P-122-MSHA. G-R P/N
47351−011. #12
AWG., 7 Conductor
Type SPC, 0.89"
"
0.03" O.D., Heavy Jack-
eted 90
_C 600/2000
Volt Royal - MSHA 122.,
Flame Resistant, Max.
Cable Length: 460V −
250 Ft., 575V − 500 Ft.
SM6D1-X30 460/3
SM6D1-X30 575/3
XP−3690−0
XP−3690−0
15952
15952
No. 6, 3 Conductor,
Type G-GC, 1.05"
$
.03" O.D., Protected By
An Instantaneous Trip
Circuit Breaker, Set At
385 Amps Max., For
460V Motors And 310
Amps Max. For 575V
Motors MSHA Flame
Resistance, 600/2000
Volt, 90
_C. Max.
Length: 500 Ft. - Cus-
tomer Furnished
Note: Instantaneous
Trip Amps Set At 385
Amps Max. For 460V,
and 310 Amps Max. for
575V To Allow For Mo-
tor Starting Current.
P-122-MSHA. G-R P/N
47325−010. #8 AWG.,
9 Conductor Type SPC,
1.05"
" 0.03" O.D., Yel-
low Jacket. 90
_C
600/2000 Volt Royal -
MSHA 122., Flame Re-
sistant, Max. Cable
Length: 460V − Com-
bined Trailing Cable
And Pump Motor Cable
Not To Exceed 500 Ft.,
575V − 300 Ft.
SM6E1-X60 460/3
SM6E1-X60 575/3
XP−3689−0
XP−3689−0
15953
15953
No. 4, 3 Conductor,
Type G-GC, 1.19"
$
.03" O.D., Protected By
An Instantaneous Trip
Circuit Breaker, Set At
660 Amps Max., For
460V Motors And 530
Amps Max. For 575V
Motors, MSHA Flame
Resistance, 600/2000
Volt, 90
_C. Max.
Length: 500 Ft. - Cus-
tomer Furnished
Note: Instantaneous
Trip Amps Set At 660
Amps Max. For 460V,
and 530 Amps Max. for
575V To Allow For Mo-
tor Starting Current.
P-122-MSHA. G-R P/N
47325−012. #6 AWG.,
9 Conductor Type SPC,
1.25"
" 0.04" O.D., Yel-
low Jacket. 90
_C
600/2000 Volt Royal -
MSHA 122., Flame Re-
sistant, Max. Cable
Length: 460V − Com-
bined Trailing Cable
And Pump Motor Cable
Not To Exceed 500 Ft.,
575V − 225 Ft.
- SM4G1-X30 575/3 1002211 thru 1241783 SM4J1-X60 460/3 1004954 thru 1241784 SM4C1-X10 460/3 1136140 and up SM4C1-X10 575/3 1136140 and up SM4C18-X10 460/3 1136140 and up SM4C18-X10 575/3 1136140 and up SM4C65-X10 460/3 915775 and up SM4C65-X10 575/3 915775 and up SM4D1-X10 460/3 1094445 and up SM4D1-X10 575/3 1094445 and up SM4D65-X10 575/3 915775 and up SM4D65-X10 460/3 915775 and up