beautypg.com

Gorman-Rupp Pumps S8B1-E100 460/3 1432260 and up User Manual

Page 49

background image

OM-06259

S SERIES PUMPS

PAGE E - 23

MAINTENANCE AND REPAIR

To fill the seal cavity, remove the pipe plug (11) and
add the recommended grade of submersible
pump oil. Apply `Loctite Pipe Sealant With Teflon
No. 592' or equivalent to the threads of the pipe
plug, before reinstalling the plug.

See Table E-2 for quantity of lubricant when lubri­

cating a dry (overhauled) pump. See Table E-3 for
lubricant specifications.

The grade of lubricant used is critical to the opera­
tion of this pump. Use premium quality hydraulic oil
as specified in Table E-3. Oil must be stored in a
clean, tightly closed container in a reasonably dry
environment.

Table E-2. Oil Quantity

Pump Model

Seal Cavity

Motor Cavity

S8B1

768 ounces (22,7 liters)

224 ounces (6,6 liters)

Table E-3. Pump Oil Specifications

Specifications:

Type

Premium high viscosity index, anti‐wear hydraulic oil

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viscosity (SSU @ 104

_F [40_C])

110 to 155

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Dielectric

26,000 (volts‐min)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Acceptable alternate suppliers:

Gulf Oil Company

Gulf Harmony AW Hydraulic Fluid MG 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . .

Texas Oil Company

Rando HD 32 or HD AZ 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Sun Oil Company

Sunvis 816 or 916

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

BP (Also Boron)

Energol‐HLP 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Shell Oil Company

Tellus 32, Tellus T‐23 or T32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Viscosity (SSU @ 210

_F [100_C])

40 to 50

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Recommended supplier:

Gulf Oil Company

Gulf Harmony 32 AW

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

ARCO

Duro 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Exxon (Also Esso)

Nuto H 32

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Petro‐Canada

Harmony HVI 22

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Motor Housing Cavity

With the pump in an upright position, remove the
pipe cap (27) on the top of the pump. See Table
E-2 and add the recommended quantity of lubri­
cant to the motor cavity. Maintain the oil at this
level
. Apply `Loctite Pipe Sealant With Teflon No.
592' or equivalent sealant to the threads of the
street tee assembly (28). Reinstall and tighten the
cap.

Never attempt to fill the motor cavity
through the drain plug (10) opening. A vol­
ume of air must be trapped above the mo­
tor to permit thermal expansion of the mo­
tor oil.