SE SERIES
OM−06488
MAINTENANCE AND REPAIR
PAGE E − 15
Seal Cavity
Pressure
(PSI)
Pump
Model
Motor Cavity
Vacuum
(In. Hg.)
Duration
(Minutes)
Duration
(Minutes)
SE1 1/2A
30
1
15
1
LUBRICATION
Seal Cavity
Check the oil level in the seal cavity before initial
startup, after the first two weeks of operation, and
every month thereafter.
Check the oil level only when the pump
is cool. If the oil level plug is removed
when the pump is hot, pressure in the
seal cavity can cause hot oil to be
ejected as the plug is removed.
To check the seal cavity oil, lay the pump on its side
and remove the seal cavity plug (56) in the motor
housing. Tip the pump and drain off a small
amount of oil into a transparent cup. If the oil level is
abnormally low, or the color milky or dark, refer to
Draining Oil From Seal Cavity in this section for
instructions and troubleshooting tips.
To fill the seal cavity, remove the seal cavity drain/fill
plug (56) and add 7 ounces (0,2 liter) of SAE No. 10
non-detergent oil. Refer to the Section B, Installa-
tion and Section C, Operations or positioning of
the pump during filling of the seal cavity. Apply
‘Loctite Pipe Sealant With Teflon No. 592.’ or equiv-
alent to the threads of the pipe plug, before rein-
stalling the plug.
Motor Cavity
The motor cavity is cooled by the liquid being
pumped. No further lubrication is required.