beautypg.com

Gorman-Rupp Pumps PA4B60-4045H 1497876 and up User Manual

Page 43

background image

OM−06228

PA SERIES

MAINTENANCE & REPAIR

PAGE E − 23

Observe the area between the shaft and
bearing retainer (23) as grease is added. If
old grease is forced out as new grease is
added, the bearing cavity is full and should
be disassembled and cleaned immediate-
ly.

There are no provisions in the bearing cavity to
drain or flush the lubricant. The pump and interme-
diate must be disassembled to completely clean
and maintain this cavity.

Under normal conditions, change the grease after
each 5000 hours of operation, or at 12 month inter-

vals, whichever comes first. Change the grease
more frequently if the pump is operated continu-
ously or installed in an environment where variable
hot and cold temperatures are common.

When lubricating a dry (overhauled) intermediate,
fill the cavity through the lubrication fitting with ap-
proximately one third pound (0,15 kg) of grease
(approximately one-third full).

For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
lubricant.

Engine

Consult the manual supplied with the engine or
contact your local engine representative.