Gorman-Rupp Pumps PA6C60-QSB4.5P 1537244 and up User Manual
Page 47
OM-06553
PA SERIES
MAINTENANCE & REPAIR
PAGE E - 25
LUBRICATION
(Figure 5)
Seal Assembly
Fill the seal cavity through the hole for the vented
plug (8) with SAE No. 30 non‐detergent oil to the
line on the sight gauge (8, Figure 4). Check the oil
level regularly and refill as required. When lubricat
ing a dry seal cavity, add approximately approxi
mately 256 oz. or 8 U.S. quarts (7,6 liters) of oil to
level indicated.
Bearings
(Figure 5)
The bearing housing was fully lubricated when
shipped from the factory. Check the oil level regu
larly through the sight gauges (5)
and maintain it at
the midpoint of the gauge. When lubrication is re
quired, remove the air vent (10) and add SAE No.
30 non‐detergent oil through the opening. When
lubricating a dry (overhauled) bearing housing, fill
the bearing cavity with approximately 40 ounces
(1,2 liters) of oil. Clean and reinstall the air vent. Do
not over‐lubricate. Over‐lubrication can cause the
bearings to over‐heat, resulting in premature bear
ing failure.
NOTE
The white reflector in the sight gauge must be posi
tioned horizontally to provide proper drainage.
Under normal conditions, drain the bearing hous
ing once each year and refill with clean oil. Change
the oil more frequently if the pump is operated con
tinuously or installed in an environment with rapid
temperature change.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.
Engine
Consult the literature supplied with the engine, or
contact your local engine representative.