Gorman-Rupp Pumps PA6C60-QSB4.5P 1537244 and up User Manual
Page 18
OM-06553
PAH SERIES
OPERATION
PAGE C - 5
conditions, change the filter more frequently. Irreg
ular performance and loss of power usually indi
cate a dirty fuel filter.
Engine Oil
The engine was lubricated for test at the factory.
However, always check the lubrication level before
startup.
Consult the manual accompanying the engine,
and change the oil filter periodically as indicated. If
operated under extremely dusty conditions,
change the filter more frequently.
Air Compressor
The air compressor was lubricated for test at the
factory. However, always check the lubrication lev
el before startup.
Consult the manual accompanying the air com
pressor and preform all duties and checks as indi
cated.
COLD WEATHER PRESERVATION
In below freezing conditions, drain the pump to
prevent damage from freezing. Also, clean out any
solids by flushing with a hose. Operate the pump
for approximately one minute; this will remove any
remaining liquid that could freeze the pump rotat
ing parts. If the pump will be idle for more than a
few hours, or if it has been pumping liquids con
taining a large amount of solids, drain the pump,
and flush it thoroughly with clean water. To prevent
large solids from clogging the drain port and pre
venting the pump from completely draining, insert
a rod or stiff wire in the drain port, and agitate the
liquid during the draining process. Clean out any
remaining solids by flushing with a hose.