Gorman-Rupp Pumps 612L20B-B 806819 and up User Manual
Page 13
OM-01919
60 SERIES
PAGE B - 6
INSTALLATION
are properly aligned (see Figure B-5). In drive sys
tems using two or more belts, make certain that the
belts are a matched set; unmatched sets will cause
accelerated belt wear.
MISALIGNED:
SHAFTS
NOT PARALLEL
MISALIGNED:
SHAFTS
NOT IN LINE
ALIGNED: SHAFTS
PARALLEL AND
SHEAVES IN LINE
Figure B-5. Alignment of V‐Belt Driven
Pumps
Tighten the belts in accordance with the belt manu
facturer's instructions. If the belts are too loose,
they will slip; if the belts are too tight, there will be
excessive power loss and possible bearing failure.
Select pulleys that will match the proper speed ra
tio; overspeeding the pump may damage both
pump and power source.
Do not operate the pump without the
guard in place over the rotating parts.
Exposed rotating parts can catch cloth
ing, fingers, or tools, causing severe in
jury to personnel.
V‐Belt Jack Shaft Drives
If the pump is to be driven at speeds exceeding
1050 rpm, the V‐belts must operate through a jack
shaft arrangement to protect the shaft bearings
from excessive stress. Failure to use a jack shaft on
high speed applications will result in premature
shaft bearing failure.