10 SERIES
OM-06541
MAINTENANCE & REPAIR
PAGE E - 18
GREASE
FITTING
CROSS
ARM
POSITION
WHEN
EMPTY
POSITION
FOR
FILLING
POSITION
WHEN
IN USE
RELIEF
HOLE
Figure 7. Automatic Lubricating Grease Cup
Bearings
(Figure 3)
The intermediate was fully lubricated when
shipped from the factory. Check the oil level regu
larly through the sight gauge (34)
and maintain it at
the middle of the gauge. When lubrication is re
quired, add SAE No. 30 non‐detergent oil through
the hole for the oil hole cover (20). Do not over‐lu
bricate. Over‐lubrication can cause the bearings to
over‐heat, resulting in premature bearing failure.
NOTE
The white reflector in the sight gauge must be posi
tioned horizontally to provide proper drainage.
Under normal conditions, drain the intermediate
once each year and refill with approximately 7‐1/2
ounces (22 mL) of clean oil. Change the oil more
frequently if the pump is operated continuously or
installed in an environment with rapid temperature
change.
Monitor the condition of the bearing lubri
cant regularly for evidence of rust or mois
ture condensation. This is especially im
portant in areas where variable hot and
cold temperatures are common.
For cold weather operation, consult the factory or a
lubricant supplier for the recommended grade of
oil.
Engine
Consult the literature supplied with the engine, or
contact your local John Deere representative.