beautypg.com

Operation - section c – Gorman-Rupp Pumps T2A3-B /F,/FM,/WW User Manual

Page 16

background image

T‐SERIES

OM-05136

OPERATION

PAGE C - 1

OPERATION - SECTION C

Review all SAFETY information in Section A.

Follow the instructions on all tags, labels and de­
cals attached to the pump.

This pump is designed to handle liquids
containing large entrained solids and
slurries. Do not attempt to pump vola­
tile, corrosive, or flammable liquids
which may damage the pump or endan­
ger personnel as a result of pump fail­
ure.

Pump speed and operating conditions
must be within the performance range
shown on page E‐1.

PRIMING

Install the pump and piping as described in IN­
STALLATION
. Make sure that the piping connec­
tions are tight, and that the pump is securely
mounted. Check that the pump is properly lubri­
cated (see LUBRICATION in MAINTENANCE
AND REPAIR
).

This pump is self‐priming, but the pump should
never be operated unless there is liquid in the
pump casing.

Never operate this pump unless there is
liquid in the pump casing. The pump will
not prime when dry. extended operation of
a dry pump will destroy the seal assembly.

Add liquid to the pump casing when:

1. The pump is being put into service for the

first time.

2. The pump has not been used for a consider­

able length of time.

3. The liquid in the pump casing has evapo­

rated.

Once the pump casing has been filled, the pump
will prime and reprime as necessary.

After filling the pump casing, reinstall
and tighten the fill plug. Do not attempt
to operate the pump unless all connect­
ing piping is securely installed. Other­
wise, liquid in the pump forced out un­
der pressure could cause injury to per­
sonnel.

To fill the pump, remove the pump casing fill cover
or fill plug in the top of the casing, and add clean
liquid until the casing is filled. Replace the fill cover
or fill plug before operating the pump.

STARTING

Consult the operations manual furnished with the
power source.

Rotation

The correct direction of pump rotation is counter­
clockwise when facing the impeller. The pump
could be damaged and performance adversely af­
fected by incorrect rotation. If pump performance
is not within the specified limits (see the curve on
page E‐1), check the direction of power source ro­
tation before further troubleshooting.

If an electric motor is used to drive the pump, re­
move V‐belts, couplings, or otherwise disconnect
the pump from the motor before checking motor
rotation. Operate the motor independently while
observing the direction of the motor shaft, or cool­
ing fan.

If rotation is incorrect on a three‐phase motor, have
a qualified electrician interchange any two of the