Troubleshooting - section d – Gorman-Rupp Pumps 86A2-4024H 1535998 and up User Manual
Page 17
OM-06413
80 SERIES
TROUBLESHOOTING
PAGE D - 1
TROUBLESHOOTING - SECTION D
Review all SAFETY information in Section A.
Before attempting to open or service the
pump:
1. Familiarize yourself with this man
ual.
2. Switch off engine ignition and dis
connect the positive battery cable
to ensure that the pump will re
main inoperative.
3. Allow the pump to completely cool
if overheated.
4. Check the temperature before
opening any covers, plates, or
plugs.
5. Close the suction and discharge
valves.
6. Vent the pump slowly and cau
tiously.
7. Drain the pump.
TROUBLE
POSSIBLE CAUSE
PROBABLE REMEDY
PUMP FAILS TO PRIME
Not enough liquid in casing.
Suction check valve contaminated or
damaged.
Air leak in suction line.
Lining of suction hose collapsed.
Leaking or worn seal or pump gasket.
Suction lift or discharge head too high.
Strainer clogged.
Add liquid to casing. See PRIMING.
Clean or replace check valve.
Correct leak.
Replace suction hose.
Check pump vacuum. Replace leaking
or worn seal or gasket.
Check piping installation and install by
pass line if needed. See INSTALLA
TION.
Check strainer and clean if necessary.
PUMP STOPS OR FAILS
TO DELIVER RATED
FLOW OR PRESSURE
Air leak in suction line.
Lining of suction hose collapsed.
Leaking or worn seal or pump gasket.
Strainer clogged.
Correct leak.
Replace suction hose.
Check pump vacuum. Replace leak
ing or worn seal or gasket.
Check strainer and clean if neces
sary.