beautypg.com

Gorman-Rupp Pumps 86A2-4024H 1535998 and up User Manual

Page 14

background image

OM-06413

80 SERIES

OPERATION

PAGE C - 2

liquid until the casing is filled. Replace the fill cover
or fill plug before operating the pump.

NOTE

This pump is self‐priming; however, it is not suited
for unattended reprime applications. In the event of
suction check valve failure and loss of prime, the
pump casing must be refilled through the fill cover
or fill plug.

STARTING

Consult the operations manual furnished with the
engine.

Starting

On initial start‐up, set the engine speed at the half‐
throttle position. Turn the keyswitch on the control
panel to “RUN” and press the “ENTER” button on
the engine control panel.

After the engine starts and the unit is fully primed,
adjust the engine RPM until the desired flow rate is
achieved.

Pump speed and operating condition
points must be within the continuous per­
formance range shown on the curve on
page E‐1.

OPERATION

Pump speed and operating condition
points must be within the continuous per­
formance range shown on the curve. (See
Section E, Page 1.)

Lines With a Bypass

If a Gorman‐Rupp Automatic Air Release Valve has
been installed, the valve will automatically open to
allow the pump to prime, and automatically close
after priming is complete (see INSTALLATION for
Air Release Valve operation).

If the bypass line is open, air from the suction line
will be discharged through the bypass line back to
the wet well during the priming cycle. Liquid will
then continue to circulate through the bypass line
while the pump is in operation.

Lines Without a Bypass

Open all valves in the discharge line and start the
power source. Priming is indicated by a positive
reading on the discharge pressure gauge or by a
quieter operation. The pump may not prime imme­
diately because the suction line must first fill with
liquid. If the pump fails to prime within five minutes,
stop it and check the suction line for leaks.

After the pump has been primed, partially close the
discharge line throttling valve in order to fill the line
slowly and guard against excessive shock pres­
sure which could damage pipe ends, gaskets,
sprinkler heads, and any other fixtures connected
to the line. When the discharge line is completely
filled, adjust the throttling valve to the required flow
rate.

Do not operate the pump against a
closed discharge throttling valve for
long periods of time. If operated against
a closed discharge throttling valve,
pump components will deteriorate, and
the liquid could come to a boil, build
pressure, and cause the pump casing to
rupture or explode.

Leakage

No leakage should be visible at pump mating sur­
faces, or at pump connections or fittings. Keep all
line connections and fittings tight to maintain maxi­
mum pump efficiency.

Liquid Temperature And Overheating

The maximum liquid temperature for this pump is
110

_ F (43_C). Do not apply it at a higher operating

temperature.

Overheating can occur if operated with the valves
in the suction or discharge lines closed. Operating
against closed valves could bring the liquid to a