Gorman-Rupp Pumps 06D1-GA 1005542 and up User Manual
Page 9
![background image](/manuals/315344/9/background.png)
OM-01256
0 SERIES
PAGE B - 2
INSTALLATION
OUTLINE DRAWING
Figure 1. Pump Model 06D1-GAR
PREINSTALLATION INSPECTION
The pump assembly was inspected and tested be
fore shipment from the factory. Before installation,
inspect the pump for damage which may have oc
curred during shipment. Check as follows:
a. Inspect the pump and gearbox for cracks,
dents, damaged threads, and other obvious
damage.
b. Check for and tighten loose attaching hard
ware. Since gaskets tend to shrink after dry
ing, check for loose hardware at mating sur
faces.
c. Carefully read all tags, decals, and markings
on the pump assembly, and perform all duties
indicated.Note the direction of rotation indi
cated on the pump. Check that the pump
shaft rotates in the required direction.
Only operate this pump in the direction in
dicated on the pump body and/or the ac
companying decal. Reverse rotation of the
shaft will adversely effect pump perform
ance, and the pump and/or gearbox could
be seriously damaged.
d. Check levels and lubricate as necessary. Re
fer to LUBRICATION in the MAINTENANCE
AND REPAIR section of this manual and per
form duties as instructed.
e. If the pump and gearbox have been stored for
more than 12 months, some of the compo
nents or lubricants may have exceeded their
maximum shelf life. These must be inspected
or replaced to ensure maximum pump serv
ice.
If the maximum shelf life has been exceeded, or if
anything appears to be abnormal, contact your
Gorman‐Rupp distributor or the factory to deter
mine the repair or updating policy. Do not put the
pump into service until appropriate action has
been taken.
VEHICLE REQUIREMENTS
The following instructions apply equally to new in
stallations, rebuilds or retrofits.