Gorman-Rupp Pumps 06D1-GA 1005542 and up User Manual
Page 28
![background image](/manuals/315344/28/background.png)
0 SERIES
OM-01256
MAINTENANCE & REPAIR
PAGE E - 8
5
_ TAPER
(APPROX.)
SLEEVE
1.00 D
1.44
FINISH ALL OVER TO
BE 50 RMS OR LESS
ENDS TO BE SQUARE
AND PARALLEL
36,6 mm
25,4 mm
IMPELLER
SHAFT
SEAL
AREA
KEYWAY
1.25 D
31,8 mm
SLEEVE DIMENSIONS
SLEEVE INSTALLED
32
Figure 3. Seal Installation Sleeve
Lubricate the tapered sleeve and position it on the
shaft. Position the rotating portion of the seal (con
sisting of the retainer, bellows and rotating ele
ment) on the sleeve, and apply even pressure
against the shoulder of the seal retainer until the ro
tating subassembly slides onto the shaft and the
seal faces contact. A push tube cut from a piece of
plastic tubing would aid this installation. The I.D. of
the tube should be approximately the same diame
ter as the I.D. of the seal spring.
Remove the tapered sleeve and install the seal
spring. Make sure that all components of the seal
are seated squarely.
Impeller Installation
(Figures 1 and 4)
Inspect the impeller (2), and replace it if cracked or
badly worn.
For maximum pump efficiency, the impeller must
be centered within the volute scroll. To verify impel
ler positioning, measure the pump casing and im
peller as shown in Figure 4. Use these measure
ments to calculate the required impeller location
(dimension E). Add or remove impeller adjusting
shims (21) to obtain dimension E.
D
B
2
A
B
2
C
D
E
Step 2
Step 1
Step 3
A+
B
2
C+
D
2
E
=
-
Figure 4. Centering Impeller Within Pump Casing
With the correct thickness of impeller adjusting
shims installed, apply `Loctite Primer Grade T', fol
lowed by `Loctite Retaining Compound No. 242' to
the keyway, impeller key (46) and shaft threads
(use no substitutes).