beautypg.com

Gorman-Rupp Pumps 08C1-GA 1026171 and up User Manual

Page 21

background image

0 SERIES

OM−01265

MAINTENANCE & REPAIR

PAGE E − 1

PUMP MAINTENANCE AND REPAIR - SECTION E

MAINTENANCE AND REPAIR OF THE WEARING PARTS OF THE PUMP WILL MAINTAIN PEAK
OPERATING PERFORMANCE.

STANDARD PERFORMANCE FOR PUMP MODEL 08C1−GA

Based on 70_ F (21_ C) clear water corrected to

0.8 specific gravity at sea level with minimum suc-
tion lift. Since pump installations are seldom identi-
cal, your performance may be different due to such
factors as viscosity, specific gravity, elevation, tem-
perature, and impeller trim.

If your pump serial number is followed by an N",
your pump is NOT a standard production model.

Contact the Gorman-Rupp Company to verify part
numbers.

Pump speed and operating condition
points must be within the continuous per-
formance range shown on the curve.