Gorman-Rupp Pumps VS3A60-B 1368380 and up User Manual
Page 15
OM-06012
ULTRA V SERIES
PAGE B - 8
INSTALLATION
Figure 5 shows a recommended alternate single
motor belt drive arrangement where the both
pump shafts are driven by separate drive belts con
nected to one motor. In this arrangement, shaft
and/or bearing loads are evenly divided between
the two pumps.
Figure 5. Alternate Single Motor Belt Drive
Arrangement
Single Motor Combination Drives
In staged applications where both pumps are driv
en by a single motor in a combination belt and cou
pling drive configuration, certain arrangements
must be used in order to ensure proper operation.
Figure 6 shows a recommended alternate single
motor combination drive arrangement, where
the first stage pump shaft is direct‐coupled to the
motor and the second stage pump shaft is driven
by belts and an idler located between the two
shafts. In this arrangement, shaft and/or bearing
loads are shared between the two pumps.
Figure 6. Alternate Single Motor Combination
Drive Arrangement
Figures 7 and 8 show single motor belt drive ar
rangements that are not recommended because
they can cause an overload condition on the shaft
and/or bearings, resulting in premature failure.
Figure 7. Improper Single Motor Belt Drive
Arrangement (Dual Belts)