Figure 5 shows a recommended alternate single
motor belt drive arrangement
where the both
pump shafts are driven by separate drive belts con­
nected to one motor. In this arrangement, shaft
and/or bearing loads are evenly divided between
the two pumps.

Figure 5. Alternate Single Motor Belt Drive

Arrangement

Single Motor Combination Drives

In staged applications where both pumps are driv­
en by a single motor in a combination belt and cou­
pling drive configuration, certain arrangements
must be used in order to ensure proper operation.

Figure 6 shows a recommended alternate single
motor combination drive arrangement
, where
the first stage pump shaft is direct‐coupled to the
motor and the second stage pump shaft is driven
by belts and an idler located between the two
shafts. In this arrangement, shaft and/or bearing
loads are shared between the two pumps.

Figure 6. Alternate Single Motor Combination

Drive Arrangement

Figures 7 and 8 show single motor belt drive ar­
rangements that are
not recommended because
they can cause an overload condition on the shaft
and/or bearings, resulting in premature failure.

Figure 7. Improper Single Motor Belt Drive

Arrangement (Dual Belts)