beautypg.com

Connection, Connecting the control panel to the switcher – Extron Electronics MMX 32 MAAP Installation User Manual

Page 3

background image

Connection

4

3

Connection

2

Input 2 pole — Connect this pole of the captive screw connector

to the appropriate connector on the connected switcher:

MMX 32 VGA A —

Remote connector, pin 4 (to control input

selection for output 1) or pin 8 (for output 2)

MMX 32 VGA MTP —

Contact 1 pin 2 (to control input

selection for output 1) or Contact 2 pin 2 (for output 2)

3

Input 3 pole —

Connect this pole of the captive screw connector

to the appropriate connector on the connected switcher:

MMX 32 VGA A —

Remote connector, pin 6 (to control input

selection for output 1) or pin 9 (for output 2)

MMX 32 VGA MTP —

Contact 1 pin 3 (to control input

selection for output 1) or Contact 2 pin 3 (for output 2)

Tally Power Connector

4

5 VDC pole — Connect this pole of the captive screw connector to

the appropriate connector on the connected switcher:

MMX 32 VGA A —

Tally Power connector, 5V pole

MMX 32 VGA MTP —

Contact connector, +5V pole for the

appropriate output.

5

Ground pole — Connect this pole of the captive screw connector

to the appropriate connector on the connected switcher:

MMX 32 VGA A —

Tally Power connector, ground pole

MMX 32 VGA MTP —

Contact connector, ground pole for

the appropriate output.

Connecting the Control Panel to the Switcher

L

R

IN

PU

T 2

IN

PU

T 1

AU

DI

O

AU

DI

O

OU

TP

UT

1

AU

DI

O

IN

PU

T 3

AU

DI

O

RE

MO

TE

AU

DI

O

RS

-23

2

+5

V

PO

W

ER

12

V

0.5

A

MA

X

2

1

1

2

3

CONT

A

C

T

Tx

R

x

SYNC -

TRI

PRE PEAK - ON

OU

TP

UT

2

RG

B/

AU

DI

O

Extron
AAP 102 w/
MMX AAP

Extron
MMX 32 MTP
Matrix Switcher

Laptop

Podium
Computer

Control

Extron
STP 22 Dual Plenum
Cable 22-162-03

Document

Camera

LCD Monitor
with Audio

Projector

Audio System

1

INP

UT

SE

LE

CT

2

3

Typical MMX 32 VGA MTP / control panel application

Only one MMX 32 AAP or MMX 32 MAAP control panel can

be used to control each output.

Extron recommends shielded twisted pair cable, such as

STP 22 Dual Plenum cable, part #22-162-03 (or equivalent),
for the connection between the control panel and the switcher.
Unshielded cable can allow crosstalk and interference between the
MMX and the control panel.

Connecting the control panel to an MMX 32 VGA A

See the drawing below. The wire connected to the 5 VDC pole

(

4

on pages 2 and 3) should not be daisy chained. The power

for each AAP or MAAP must come directly from the Tally Power
connector on the MMX switcher.

See the drawing below. The wire connected to the Ground pole

(

5

on pages 2 and 3) should not be shared or jumpered between

two AAPs and/or MAAPs. Run a separate ground wire for each
AAP and/or MAAP. Use the drain wire of the cable for ground.

The drawing below shows a control panel wired to select the input

tied to MMX 32 VGA A output 2, using pins 7, 8, and 9 on the
Remote connector. To select the input tied to output 1, use pins 1,
4, and 6 on the Remote connector.

L

R

POWER

12V
.5A MAX

INPUT 2

INPUT 1

AUDIO

AUDIO

OUTPUT 1

OUTPUT 2

INPUT 3

R

H

G

B

V

AUDIO

REMOTE

AUDIO

TALLY

OUT

5V

MMX 32 VGA A

MMX 32 AAP

Red +5V

Extron
STP 22 Dual Plenum
Cable 22-162-03

White

Green

Blac

k

Ground ( )

Pins 7, 8, and 9

Wiring diagram for a typical MMX 32 VGA A application