beautypg.com

Power cable connections, Applying power, Extron contact information – Extron Electronics DVI DA4 Setup Guide User Manual

Page 2: Dvi da2 and dvi da4 setup guide (continued), Step 3 — power cable connections, Step 4 — applying power

background image

© 2010 Extron Electronics. All rights reserved.

68-1376-50

Rev C
04 10

Extron

USA - West

Headquarters

+800.633.9876

Inside USA / Canada Only

+1.714.491.1500

+1.714.491.1517 FAX

Extron

USA - East

+800.633.9876

Inside USA / Canada Only

+1.919.863.1794

+1.919.863.1797 FAX

Extron

Europe

+800.3987.6673

Inside Europe Only

+31.33.453.4040

+31.33.453.4050 FAX

Extron

Asia

+800.7339.8766

Inside Asia Only

+65.6383.4400

+65.6383.4664 FAX

Extron

Japan

+81.3.3511.7655

+81.3.3511.7656 FAX

Extron

China

+400.883.1568

Inside China Only

+86.21.3760.1568

+86.21.3760.1566 FAX

Extron

Middle East

+971.4.2991800

+971.4.2991880 FAX

DVI DA2 and DVI DA4 Setup Guide (Continued)

Step 3 — Power Cable Connections

Connect the 12 VDC power supply to the power receptacle of the unit.

12V

0.4A MAX

POWER

Power Supply

Output Cord

SECTION A–A

Ridges

Smooth

A

A

DC Power Cord
Captive Screw Connector

AC Power Cord

Ground

+12 VDC

External

Power Supply

(12 VDC, 1 A )

CAUTION: This product is intended to be supplied by a Listed Power Unit marked “Class 2” or “LPS”,

rated 12 VDC, maximum 1.0 A. Always use a power supply supplied or specified by Extron. Use
of an unauthorized power supply voids all regulatory compliance certification and may cause
damage to the supply and the end product.

Unless otherwise stated, the AC/DC adapters are not suitable for use in air handling spaces or
in wall cavities. The power supply is to be located within the same vicinity as the Extron A/V
processing equipment in an ordinary location, Pollution Degree 2, secured to the equipment rack
within the dedicated closet, podium, or desk.

The installation must always be in accordance with the applicable provisions of National Electrical
Code ANSI/NFPA 70, article 75, and the Canadian Electrical Code part 1, section 16. The power
supply shall not be permanently fixed to building structure or similar structure.

NOTES: The length of the exposed wires in the stripping process is critical. The ideal length is

3/16 inches (5 mm). If the exposed section is longer, the exposed wires may touch, causing a short
circuit between them. If it is shorter, the wires can be easily pulled out even if tightly fastened by
the captive screws.

Do not tin the wires. Tinned wire does not hold its shape and can become loose over time.

Step 4 — Applying Power

NOTE: Output 1 is used as DDC reference and Hotplug Detect and a local monitor must be

connected to it before the source device is powered on. Since Output 1 is used for reference, all
displays connected to the other outputs must be capable of handling resolutions greater than or
equal to that of Output 1.

Power on the local monitor.

Power on the display devices.

Power on the source input device.