beautypg.com

Connector and cable details, Tp cable termination and recommendations, Item – Extron Electronics DTP DVI 230 User Guide User Manual

Page 12

background image

DTP DVI 230 Tx/Rx Transmitter and Receiver • Installation and Operation

6

j

RS-232 and IR connector — Connect a serial RS‑232 signal, a modulated IR

signal, or both to this 3.5 mm, 5‑pole captive screw connector for bidirectional RS‑232
and IR communication (see

RS-232 and IR connector wiring

on page 9 to wire the

connector).

k

Power input connector — Plug the included external 12 VDC power supply into

either this 2‑pole connector

or the power input connector on the transmitter (see

item

f

on the previous page) (see

Power supply wiring

on page 8 to wire the

connector).

NOTES:

One power supply is included with the transmitter and

normally can power

both units.

If you have removed the ground jumpers (see

Disconnecting the Ground

on page 11) because of ground potential differences, one DTP DVI 230 unit
cannot remotely power the other unit. Each unit requires a local power
supply.

Connector and Cable Details

TP cable termination and recommendations

Figure 5 details the

TIA/EIA T 568B wiring standard. Use this standard to terminate TP

cables with RJ‑45 connectors.

5

Pin

1

2
3

6
7
8

4

Wire color

White-green

Green

White-orange

White-blue

Orange

White-brown

Brown

Blue

TIA/EIA T

568 B

Side

12345678

Insert

Twisted

Pair Wires

Pins:

Figure 5.

TP Cable Termination

NOTE: Do

not use Extron UTP23SF‑4 Enhanced Skew‑Free AV UTP cable or STP201

cable to link the transmitter and receiver. The DTP DVI 230 Tx/Rx does not work