DTP DVI 230 Tx/Rx Transmitter and Receiver • Installation and Operation
6
j
RS-232 and IR connector — Connect a serial RS‑232 signal, a modulated IR
signal, or both to this 3.5 mm, 5‑pole captive screw connector for bidirectional RS‑232
and IR communication (see
RS-232 and IR connector wiring
on page 9 to wire the
connector).
k
Power input connector — Plug the included external 12 VDC power supply into
either this 2‑pole connector
or the power input connector on the transmitter (see
f
on the previous page) (see
on page 8 to wire the
connector).
NOTES:
•
One power supply is included with the transmitter and
normally can power
both units.
•
If you have removed the ground jumpers (see
on page 11) because of ground potential differences, one DTP DVI 230 unit
cannot remotely power the other unit. Each unit requires a local power
supply.
Connector and Cable Details
TP cable termination and recommendations
Figure 5 details the
TIA/EIA T 568B wiring standard. Use this standard to terminate TP
cables with RJ‑45 connectors.
5
Pin
1
2
3
6
7
8
4
Wire color
White-green
Green
White-orange
White-blue
Orange
White-brown
Brown
Blue
TIA/EIA T
568 B
Side
12345678
Insert
Twisted
Pair Wires
Pins:
Figure 5.
TP Cable Termination
NOTE: Do
not use Extron UTP23SF‑4 Enhanced Skew‑Free AV UTP cable or STP201
cable to link the transmitter and receiver. The DTP DVI 230 Tx/Rx does not work