beautypg.com

Command function sis command, Response, Additional description – Extron Electronics DTP T USW 333 User Guide User Manual

Page 22

background image

DTP T USW 333 • Remote Control

17

Command Function

SIS Command

(Host to Unit)

Response

(Unit to Host)

Additional description

Input 1 (only) video format

Set format

1*

X1!

\

Typ

X1!]

Set input 1 to format

X1!

.

Example:

1*0\

Typ0

]

Set input 1 to autodetect.

View format

1\

X1!]

View set format.

View detected format

1*\

X1!]

View detected format (

X1!

= 1 or 2 only).

Video mute

Mute video

1B

Vmt1

]

Output no video signal.

Unmute video

0B

Vmt0

]

Output selected video input.

Read video mute

B

X#]

Mute status =

X#

.

Analog audio mute

Mute analog audio

1Z

Amt1

]

Output no analog audio signal.

Unmute analog audio

0Z

Amt0

]

Output analog audio input.

Read analog audio mute

Z

X#]

Analog audio mute status =

X#

.

Disable (Mute) HDMI Output Embedded Audio

Enable HDMI audio output

E

1AFMT

}

Afmt1

]

Enable HDMI audio. (

Default)

Disable HDMI audio output

E

0AFMT

}

Afmt0

]

Disable HDMI audio.

View HDMI audio configuration

E

AFMT

}

X#]

Device Name

Set the unit name

EX1@

CN

}

Ipn

•X1@]

Change the name to one of your choosing.

Set unit name to factory default

E•

CN

}

Ipn

DTP-T-USW-333

]

Set name to default.

View unit name

E

CN

}

X1@]

Reset

Reset to factory setting

E

ZXXX

}

Zpx

]

Reset to factory defaults.

Reset to factory setting and device
name

E

ZQQQ

}

Zpq

]

Reset to factory defaults, including,
default name (

DTP-T-USW-333

).

Information requests

Information request

I

In

X!•

Aflw

X!•

Ausw

X@•

Vmt

X#•

Amt

X#]

Example:

I

In1

Aflw2

Ausw1

Vmt1

Amt0

]

Input 1 is selected, analog audio is
assigned to input 2, the switcher is in
auto-input switching (high) mode, video
is muted and analog audio is unmuted.

Request part number

N

60-nnnn-nn

]

See the Extron website,

www.extron.com

, for part numbers.

Query controller firmware version

Q

X1#]

Example:

Q

1.23

]

The factory-installed controller firmware
version is 1.23 (sample value only).

Verbose mode

NOTE: If tagged responses are enabled (modes 2 and 3), all “view” commands return the prefix and the value, just as the “set”

commands do. For example, the View front panel switch mode (

E

AUSW

}

) command returns “

Ausw

X@]

“.

Set verbose mode

EX1$

CV

}

Vrb

X1$]

Read verbose mode

E

CV

}

X1$]

NOTE:

X!

= Input number

0

or

1

through

3

(

0

= always output for audio assignment)

X@

= Switch mode

0

= Manual (

default)

1

= Auto-input switching high

2

= Auto-input switching low

X#

= Status

0

= Off, disabled, or not detected

1

= on, enable, or detected

X1!

= Analog input video format

0

= Auto detect (

default)

1

= RGB (VGA)

2

= YUV/component video

X1@

= Switcher name

A text string of up to 24 alphanumeric characters and minus sign/hyphen (-).

X1#

= Firmware version number to second decimal place (x.xx)

X1$

= Verbose mode

0 = clear/none (default)

2 = tagged responses for queries

1 = verbose mode (default for RS-232 or USB)

3 = verbose mode and tagged for queries