Normal operation, Temperatures available in default mode °c, Temperatures available in high temperature mode °c – John Wood Takagi - 910 User Manual
Page 19

19
NORMAL OPERATION
Flow rate to activate the 910:
1.9 l/min (0.5 GPM (US))
Flow rate to keep the 520H running:
1.5 l/min (0.4 GPM (US))
•
•
Without Remote Controller
1.
Open a hot
water tap.
2. Mix cold water
with the hot to
get the correct
t e m p e r a t u r e
water.
3. Close the hot
water tap.
Hot Water temperatures over 52°C (125°F)
can cause severe burns instantly or death
from scalding.
The outlet hot water temperature of
the water heater is factory set at 49°C
(120°F).
Feel the water temperature before bath-
ing or showering.
•
•
With Remote Controller Installed: TM-RE30
(Optional)
1. Press the power ON/OFF button.
When ON, green LED is lit.
The temperature and the
time will be displayed on the
remote controller.
2. Set temperature. (Example 43°C (110°F))
Temperatures available in default mode
°C
38
40.5
43
46
49
52
55
57
60
63
65.5
68
71
74
77
79
°F
100
105
110
115
120
125
130
135
140
145
150
155
160
165
170
175
Temperatures available in High Temperature mode
°C
38
46
49
52
55
57
60
63
65.5
68
71
74
77
79
82
85
°F
100
115
120
125
130
135
140
145
150
155
160
165
170
175
180
185
DO NOT set to 85°C (185°F) if you use your water heater in
recirculation system (refer to pg. 32).
3. Open a hot water tap.
Mix cold water with the hot if you need.
4. Close the hot water tap.
*To change the remote controller’s mode from Default Mode
to High Temperature Mode, follow the procedures below
(the remote controller must be installed prior to operating
these procedures):