John Wood Takagi - 110-310-510 User Manual
Page 32

32
110 & 310
510
Malfunction description
Diagnosis
Red LED
TK-RE02
TM-RE30
N/A
N/A
441
Flow Sensor Failure (Easy-
Link System only)
Check for connection/breakage of
wires and/or debris on the flow sensor
impeller. (Part #402, 717)
•
Six Times
51
510
Abnormal Gas Solenoid Valve
Check for connection/breakage of
wires (Part #708) and/or burn marks
on the computer board (Part #701).
•
55
N/A
Abnormal Main Gas Valve
Check for connection/breakage of
wires (Part #708) and/or burn marks
on the computer board (Part #701).
•
Four Times
61
611
Fan Motor Fault
Check for connection/breakage of
wires, dust buildup in the fan motor
(Part #103) and/or burn marks on the
computer board (Part #701).
Check for frozen/corrosion of connec-
tors (Part #103).
•
•
N/A
N/A
651
Flow Adjustment Valve Fault
(Easy-Link System only)
Inspect the flow adjustment valve (Part
#402), for connection/breakage of
wires (Part #718), locked motor drive
due to scale buildup, and/or water
leakage.
•
One Time
70
701
Computer board Fault
Check for connection/breakage of
wires (Part #714) and/or burn marks
on the computer board (Part #701).
Check the power supply of the water
heater.
•
•
Six Times
72
721
False Flame Detection
Check if condensate drain is installed
on the vent collar of the water heater.
Check if there is leaking from heat
exchanger (Part #401).
•
•
N/A
74
741
Miscommunication between
water heater and remote
Controller
Check the model type of the remote
controller.
Inspect the connections between the
water heater and remote controller.
Check the power supply of the water
heater.
•
•
•
N/A
N/A
761
Miscommunication in Easy-
Link system
Check if the connections between the
parent unit and the child units are cor-
rect. Refer to pg. 20-22.
•