Vent Termination Clearances
Canada
U.S.A
Direct vent and other
than Direct Vent
Direct
vent
Other than
Direct Vent
A
Clearance above grade, veranda, porch, deck, or balcony.
1 foot
1 foot
1 foot
B Clearance to window or door that may be opened
3 feet
1 foot
4 feet from below or
side opening. 1 foot
from above opening.
C
Clearance to permanently closed window
*
*
*
D
Vertical clearance to ventilated soffit located above the
vent terminator within a horizontal distance of 2 feet
(61cm) from the center line of the terminator.
*
*
*
E
Clearance to unventilated soffit
*
*
*
F
Clearance to outside corner
*
*
*
G
Clearance to inside corner
*
*
*
H
Clearance to each side of center line extended above
meter/regulator assembly
3 feet
*
*
I
Clearance to service regulator vent outlet.
3 feet
*
*
J
Clearance to non-mechanical air supply inlet to building or
the combustion air inlet to any other application
3 feet
1 foot
4 feet from below or
side opening. 1 foot
from above opening.
K
Clearance to mechanical air supply inlet.
6 feet
3 feet
3 feet
L
Clearance above paved sidewalk or paved driveway
located on public property.
7 feet
*
7 feet
M
Clearance under veranda, porch deck, or balcony.
1 foot
*
*
* For clearances not specified in CSA B149.1 Natural Gas and Propane Installation Code, please use clearances in
accordance with local installation codes and the requirement of the gas supplier.