SPECIFICATIONS
Model
110
310
510
Natural Gas Input
(Operating Range)
Min.: 19,500 BTU/h
Max.: 140,000 BTU/h
Min.: 11,000 BTU/h
Max.: 190,000 BTU/h
Min.: 11,000 BTU/h
Max.: 199,000 BTU/h
Propane Input
(Operating Range)
Min.: 19,500 BTU/h
Max.: 140,000 BTU/h
Min.: 11,000 BTU/h
Max.: 190,000 BTU/h
Min.: 11,000 BTU/h
Max.: 199,000 BTU/h
Gas Connection
3/4” NPT
Water Connections
3/4” NPT
Water Pressure
15 - 150 psi*
Inlet
Pressure
Natural Gas
Min. 5.0” WC, Max. 10.5” WC
Propane
Min. 8.0” WC, Max. 14.0” WC
Manifold
Pressure**
Natural Gas
2.0” WC
2.0” WC
2.0” WC
Propane
2.5” WC
3.7” WC
3.7” WC
Weight
13Kg (28.7 lbs.)
15.7Kg (34.6 lbs.)
Dimensions
520mm(H) x 351mm(W) x 170mm(D)
H20.5” x W13.8” x D6.7”
520mm(H) x 351mm(W) x D216mm(D)
H20.5” x W13.8” x D8.5”
Ignition
Electric Ignition
Electric
Supply
120 VAC, 60 Hz
Consumption
Operation
73.1 W / 0.61 A
87.6 W / 0.73 A
89.8 W / 0.75 A
Standby
6.2 W / 0.05 A
6.2 W / 0.05 A
6.2 W / 0.05 A
Freeze-Protection
111 W / 0.93 A
111 W / 0.93 A
111 W / 0.93 A
* 40 psi or above is recommended for maximum flow.
** The Manifold Pressure is the factory setting and generally should not need adjustment.