beautypg.com

John Wood Electric Water Heaters - NEW User Manual

Page 18

background image

18

11. A new gasket should be used in all cases to prevent a possible

water leak. Place the new element gasket on the threaded side
of the cleaned or new element and screw into tank, securing
tightly using an element wrench.

FIGURE 19.

12. Close the water heater drain valve by turning the handle to the

right (clockwise). The drain valve is on the lower front of the water
heater.

13. Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when
the water heater is in use.

14. To ensure complete fi lling of the tank, allow air to exit by opening

the nearest hot water faucet. Allow water to run until a constant fl ow
is obtained. This will let air out of the water heater and the piping.

Never use this water heater unless it is completely full of water. To
prevent damage to the tank and heating element, the tank must be
fi lled with water. Water must fl ow from the hot water faucet before
turning “ON” power. The manufacturer will not warrant any elements
damaged by failure to follow instructions.

15. Check element for water leaks. If leakage occurs, tighten element

or repeat Steps 2 and 3, remove element and reposition gasket.
Then repeat Steps 10 through 14.

16. Reconnect the two wires to the element and then check to make sure

the thermostat remains fi rmly against the surface of the tank.

FIGURE 20.

17. Replace terminal cover on thermostat making sure the locking

tabs on the terminal cover are in place.

18. Fold down the insulation so that it covers the thermostat and

element. See Figure 21.

19. Replace outer door.

20. Turn “ON” electric power to water heater.

FIGURE 21.

DRAIN VALVE WASHER REPLACEMENT

(See Figure 22)

1. Follow the “Draining and Flushing” instructions.

2. Turning counter clockwise (

), remove the hex cap below the

screw handle.

3. Remove the washer and put the new one in place.

4. Screw the handle and cap assembly back into the drain valve

and retighten using a wrench. DO NOT OVER TIGHTEN.

5. Follow instructions in the “Filling The Water Heater” section.

6. Check for leaks.

FIGURE 22.

SERVICE

If a condition persists or you are uncertain about the operation of
the water heater contact a service agency.