7. Properly assembled valve components will immediately seal to moderate pressure (100 PSI or less). For maximum

pressure resistance, allow the Loctite 567 or Rector Seal No. 5 thread sealant to cure for 24 hours. PTFE tape typically

does not require curing to achieve maximum pressure resistance.

Insulation

Bell & Gossett recommends that insulation be attached to the Model 3DV Triple Duty Valve after the system has been

balanced and the completed V1000265 tag has been wired to the Triple Duty Valve.

NOTE: Tape or other acceptable means should be used to secure the insulation to the Model 3DV Triple Duty Valve.

NOTICE: The use of thread sealants/lubricants on threads also provides lubricity. Over application of torque

may cause damage to the valve port or component.

Component

Torque

Size

Type

1/4” NPT

P/T Readout Port, Drain Plug

9.0 ft.-lbs + 3.0 ft.-lbs. / -0

Loctite and Loctite 567 are registered trademarks of Henkel AG & Co. RectorSeal No. 5 is a registered trademark of