Chem-pro, Series operation, Paddlewheel sensor signal input wiring – Xylem C3V CHEMICAL METERING PUMPS User Manual
Page 11: 0 c3v external input/output signal connection

Page 10
Page 11
C3
C3
Stop and
Start the pump
Decrease
output speed
Increase
output speed
C3F
Series Operation
The C3F is a powerful yet simple to
operate metering pump.
Blue-White Industries
Made in the USA
tm
CHEM-PRO
Diaphragm
Failure
Detection
C3F | Diaphragm Metering Pump
NEMA 4X
IP66
To start the pump, press the
Start / Stop button
To increase the output, press
the Up button
To decrease the output, press
the Down button
To stop the pump, press the
Start / Stop button
To prime the pump, press the Up button and the Start / Stop
button at the same time. The pump will run in prime mode for
60 seconds at 100% output.
To stop primming before the 60 seconds, press the Start / Stop
button.
+
Series
6.1 How To Operate The C3F
Priming the C3F
SIGNAL INPUT/OUTPUT WIRE COLOR CODES
WIRE COLOR CODE
INPUT TYPE
MOTOR ON SIGNAL
5-20V DC open collector output
closed while motor is energized
FLOW VERIFICATION SENSOR (FVS)
ALARM RELAY
connect 2-conductor plug to either
normally open (NO) (factory default)
or normally closed (NC) side of receptacle.
3 AMP MAX @ 125VAC (24VDC)
BROWN (+) & BLACK (-)
PURPLE & PURPLE
WHITE (+) & BLACK (-)
BLUE (+) (non-powered) & BLACK (-)
ORANGE (+) (non-powered) & BLACK (-)
RED/WHITE (+ 20VDC)
BLACK (-)
YELLOW (signal)
CONTACT (10v @ 2 mA max)
HALL EFFECT, NPN
RED (+) & WHITE (-)
PADDLEWHEEL SENSOR SIGNAL INPUT WIRING
PADDLEWHEEL SENSOR
WIRE COLOR CODE
BLUE-WHITE
PADDLEWHEEL
SENSOR TYPE
MODEL FH
HALL EFFECT SENSOR
BLACK (-)
RED (+)
PUMP INPUT
WIRE COLOR CODE
MODEL FC
AC SINE WAVE SENSOR
BARE (signal)
BLACK (-)
RED (+ 20VDC)
WHITE (signal)
BLACK (-)
RED (+)
BLACK (-)
WHITE (+)
4-20 mA
0-10 VDC
AC sine wave, TTL, CMOS
7.0 C3V External Input/Output Signal Connection
C3V will accept a variety of external control input signals: 4-20mA, 0-10VDC,
TTL, CMOS, AC Sine waves, contact closures, Hall Effect, NPN. The 4-20mA
and 0-10 VDC loops must be powered. Two types of frequency inputs, AC sine
waves (magnetic coils type outputs) and Digital Square waves (Hall Effect
signals, contact closures), are acceptable.
All wiring connections are to be made inside of the junction box located on the
side of the C3V. liquid-tite connectors are supplied and should be used for the
external signal cables. The signal input wires are color coded to the type of
signal being used.