beautypg.com

H-424ms – Xylem H-424MS V1.1 User Manual

Page 18

background image

Example of a H-424MS "aI!" command:

"a12 DAA H-424vvvS#nnnnnnVkkk"

H-424MS implementation of the optional 13 character field:

S#nnnnnnVkkk

(12 bytes total)

Where:

"nnnnnn"

is a six character sensor serial number

"kkk"

is a three digit sensor firmware revision level

Example of a "Change Sensor Address" command:

Command

Response

Description

-------------

------------------------

----------------------------

"aA2!"

"2"

Change sensor address to "2"

2.7 Change Sensor Address

The Change Sensor Address Command allows the sensor address to be changed. The address is
stored in non-volatile EEPROM within the sensor. The H-424MS will not respond if the
command was invalid, the address was out of range, or the EEPROM programming operation
failed.

Command

Response

Description

-------------

-------------------------

---------------------------

"aAn!"

"n"

Change sensor address

Where:

a

is the current (old) sensor address ("0-9", "A-Z", "a-z", "*", "?"). An ASCII "*"
may be used as a "wild card" address if the current address is unknown and only
one sensor is connected to the bus.

A

is an upper-case ASCII character.

n

is the new sensor address to be programmed ("0-9", "A-Z", "a-z", "*", "?").

NOTE: To verify the new address use the "Identify Command."

2-6 SDI-12 Command and Response Protocol

H-424MS