Example of a H-424MS "aI!" command:
"a12 DAA H-424vvvS#nnnnnnVkkk
H-424MS implementation of the optional 13 character field:
S#nnnnnnVkkk
(12 bytes total)
Where:
"nnnnnn"
is a six character sensor serial number
"kkk"
is a three digit sensor firmware revision level
Example of a "Change Sensor Address" command:
Command
Response
Description
-------------
------------------------
----------------------------
"aA2!"
"2
Change sensor address to "2"
2.7 Change Sensor Address
The Change Sensor Address Command allows the sensor address to be changed. The address is
stored in non-volatile EEPROM within the sensor. The H-424MS will not respond if the
command was invalid, the address was out of range, or the EEPROM programming operation
failed.
Command
Response
Description
-------------
-------------------------
---------------------------
"aAn!"
"n
Change sensor address
Where:
a
is the current (old) sensor address ("0-9", "A-Z", "a-z", "*", "?"). An ASCII "*"
may be used as a "wild card" address if the current address is unknown and only
one sensor is connected to the bus.
A
is an upper-case ASCII character.
n
is the new sensor address to be programmed ("0-9", "A-Z", "a-z", "*", "?").
NOTE: To verify the new address use the "Identify Command."
2-6 SDI-12 Command and Response Protocol