H-4161

Installation And Maintenance 2-3

2.7 Programming the Module Mode setting

The H-4161 can either “monitor” SDI-12 communication between a data logger and its sensors, or

“initiate” measurements to a dedicated sensor connected to the auxSDI-12 terminal. The H-4161 comes

from the factory with Module Mode = 0 (monitor). The extended commands to examine or change the

Module Mode are explained in Chapter 3.

2.8 Programming the Monitored Address setting

As a data monitor, the H-4161 passively monitors communication between the data recorder and its SDI-

12 sensors. The H-4161 waits for, and collects data from a specified sensor. The data recorder must

initiate any sensor measurements. The H-4161 comes from the factory with the Monitored Address = Z.

If you wish to monitor data from another sensor you must change the monitored address to the desired

value. This setting is not used if Module Mode = 1 (initiate). The extended commands to examine or

change the Monitored Address are explained in Chapter 3.

2.9 Programming the Monitored Parameter setting

Each SDI-12 sensor can make up to nine separate measurements or “parameters”. The data recorder

collects the measurement data using “aD0!” - “aD9!” commands. The Monitored Parameter setting

controls which of the nine data parameters is to be monitored by the H-4161. The H-4161 also monitors

the data sent in response to the new concurrent SDI-12 V1.2 “aR0" data collection commands. The H-

4161 comes from the factory with Monitored Parameter = 1. This setting should work with most

sensors. The extended commands to examine or change the Monitored Parameter are explained in

Chapter 3.

2.10 Programming the AutoScan Command setting

When the Module Mode =1 (initiate), the H-4161 actively initiates measurements and collects the

response from the sensor attached to the auxSDI port. The H-4161 normally issues an “0M!” command

to the auxSDI port. If desired, the H-4161 can be programmed to issue other commands such as “0M1!”

(“0M1" to “0M9!”). The extended commands to examine or change the AutoScan Command are

explained in Chapter 3.

2.11 Programming the Measure Rate setting

When Module Mode = 1 (initiate), the H-4161 initiates measurements to the sensor attached to the

auxSDI port. The measurement interval is controlled by the Measure Rate setting. If the Measure Rate

is set to a value less than the time it take to make the actual measurement, measurements will be made

back-to-back, as fast as possible. The H-4161 comes from the factory with Measure Rate = 0 (seconds).

This setting is not used if Module Mode = 0 (monitor).