Aquavar solo – quick installation guide, Quick start guide – Xylem IMS SOLOQ 1 Aquavar SOLO Quick Installation Guide User Manual
Page 5

Aquavar SOLO – Quick Installation Guide
Recommended 1AS15 Overload Settings - All Motor Brands
Motor
HP Brand
Motor
No.
Set Dial
Type
SFA
Wires
On ²
.5
CentriPro, Pentek
4.7
2
4.7
2 wire
.75
CentriPro, Pentek
6.4
2
6.4
Gen 1
1
CentriPro, Pentek
9.1
2
9.1
1.5
CentriPro, Pentek
11.0
2
11.0
0.5
CentriPro, Pentek
4.7
2
4.7
2 wire 0.75
CentriPro, Pentek
6.2
2
6.3
Gen 2 ³
1
CentriPro, Pentek
8.1
2
8.3
1.5
CentriPro, Pentek
10.4
2
11
.5
Franklin / Grundfos
6
2
6.3
2 wire
.75
Franklin / Grundfos
8 / 8.4
2
8.3
1
Franklin / Grundfos
9.8
2
9.7
1.5
Franklin / Grundfos
13.1 ¹
2
12.2
.5
CentriPro, Pentek
6.3
3
6.3
3 wire
.75
CentriPro, Pentek
8.3
3
8.3
Gen 1
1
CentriPro, Pentek
9.7
3
9.7
1.5
CentriPro, Pentek
11.1
3
11.1
2
CentriPro, Pentek
12.2
3
12.2
.5
CentriPro,
Pentek
6.1 3 6.3
3 wire
.75
CentriPro,
Pentek
7.8 3 8.3
Gen 2 ³
1
CentriPro,
Pentek
9.4 3 9.7
1.5
CentriPro, Pentek
10.9
3
11
2
CentriPro, Pentek
12.2
3
12.2
.5
Franklin / Grundfos
6
3
6.3
.75
Franklin / Grundfos
8 / 8.4
3
8.3
3 wire
1
Franklin / Grundfos
9.8
3
9.7
1.5
Franklin / Grundfos 11.5 / 11.6
3
11.5
2
Franklin / Grundfos
13.2 ¹
3
12.2
SOLO Dial Setting
Overload Current
Setting Setting
1
4.7
2
6.3
3
6.4
4
8.3
5
9.1
6
9.7
7
11.0
8
11.1
9
11.5
10
12.2
Overload Setting
Dial is located
on the UIB
(User Interface
Board) inside the
controller.
QUICK START GUIDE
IMS-SOLOQ-3
¹ Amps are higher than controller overload range - use of 1AS15 on these motors will limit current and reduce
performance.
² Note: It is acceptable to use a higher setting than the 2-wire motor maximum amperage because the 2-wire motor's
on winding overloads will protect the motor while the higher SOLO setting will not inhibit performance.
³ Gen 2 motors - 2-Wire were released for sale in Nov/Dec 2011, 3-Wire will be available Feb/March 2012.