Xylem IMS SOLOQ 1 Aquavar SOLO Quick Installation Guide User Manual
Page 4

FAULT CODES
No Light: Low Voltage or No Voltage to Controller
Green Light Codes:
• Constant Green - Unit in Standby: system is Off or system detected low
voltage, below 190 VAC and is waiting for voltage to increase to acceptable
level.
• Blinking Green - Pump is running: all is normal
Red Light Codes:
• Constant Red - Controller Error: internal controller issue, replace controller.
• 2 Blinks - Dry Well: controller will restart automatically
• 3 Blinks - Transducer Fault: controller will not run if the signal from the
transducer is disconnected or out of tolerance.
• 4 Blinks - Over Current: controller will attempt to restart three times before
displaying this fault. To clear the fault, turn power off, wait 1 minute, turn
power on. Fault may be caused by setting Overload Dial on too low a setting.
• 5 Blinks - Short Circuit: controller will attempt to restart three times, to clear,
turn power off, wait 1 minute, turn power on.
• 6 Blinks - Ground Fault: controller will not restart - To clear the fault, turn
power off, wait 1 minute, turn power on.
• 7 Blinks - Temperature: controller will restart automatically when the
temperature reaches an acceptable level.
• 8 Blinks - Open Lead: controller will not restart. To clear the fault, turn power
off, wait 1 minute, turn power on.
• 9 Blinks - Low Pressure Cut-off: Controller will not restart. Pressure 20 PSI
below set point for 30 seconds. May be a broken pipe or tripped pressure
relief valve.
Note - In many instances the controller is blamed for faults caused by bad motors, tanks
with incorrect or no air charge, poor wiring and/or improper grounding. Since the SOLO
may be used to retrofit an existing installation into a variable speed system, IM229 includes
instructions on checking Motor Insulation Resistance and Winding Resistance. Before
replacing a SOLO drive on a retrofit installation please perform these tests to verify the
motor and wire are in good condition and the tank pressure is set properly.
Xylem Inc.
www.xyleminc.com
© 2012 Xylem Inc. IMS-SOLOQ-2 January 2012